Mobile QR Code QR CODE

Journal of the Korea Concrete Institute

J Korea Inst. Struct. Maint. Insp.
  • Indexed by
  • Korea Citation Index (KCI)
Title Design Evaluation of the Post-installed Anchor considering Effective Embedded Depth and Concrete Strength
Authors 허무원(Moo-Won Hur) ; 채경훈(Kyoung-Hun Chae) ; 원재식(Jae-Sik Won) ; 박태원(Tae-Won Park)
DOI https://doi.org/10.11112/jksmi.2021.25.3.13
Page pp.13-20
ISSN 2234-6937
Keywords 후설치 앵커; 묻힘 깊이; 변동계수; 상관계수; 설계식 Post-installed anchor; Embedded depth; Coefficient of variation; Correlation number; Design equation
Abstract Post-installed anchor is a structural material that connects structural and non-structural members to existing concrete members. However, there are cases where rebar interception and construction error occur at the site. In that case, measures are needed to prevent performance degradation of the rear-installation anchors. In this study, in order to evaluate the performance of torsional control expandable post-installed anchors for compressive strength and effective depth of the reference concrete was tested. The results of the most commonly used tests of M10 and M20 showed that had variable coefficients within 15%, satisfying the reliability presented in KCI(2017). It was also confirmed that the depth of the buried and the strength of concrete affect the strength of the pavement. Based on the results of the existing similar studies and the results of this study, the design equation of the post-installed anchor was proposed and the results were compared with the existing design.