Title A Study on Commercial Frequency Source with High Frequency Resonant Type using ZCS
Authors 김종해(Kim, Jong-Hae) ; 김동희(Kim, Dong-Hui) ; 노채균(No, Chae-Gyun) ; 구태근(Gu, Tae-Geun) ; 배상준(Bae, Sang-Jun) ; 이봉섭(Lee, Bong-Seop)
Page pp.448-454
ISSN 1975-8359
Keywords Sinusoidal ac waveform ; Discontinuous conduction mode ; Quasi-sinusoidal pulse ; Carrier frequency
Abstract This paper describes a new dc-ac inverter system which for achieving sinusoidal ac waveform makes use of parallel loaded high frequency resonant inverter consisting of full bridge. Each one of the pair of switches in the inverter is driven to synchronous output frequency and the other is driven to PWM signal with resonant frequency proportional to magnitude of sine wave. A forced discontinuous conduction mode is used to realize the quasi-sinusoidal pulse in each switching period. Therefore the inverter generates sinusoidal modulated output voltage including carrier frequency that is resonant frequency. Carrier frequency components of modulated output voltage is filtered by low pass filter. Since current through switches is always zero at its turn-on in the proposed inverter, low stress and low switching loss is achieved. Operating characteristics of the proposed system is analyzed in per unit system using computer simulation. The output voltage of if includes low harmonics and it is almost close to sine wave. Also, the theoretical analysis is proved through the experimental test.