Title Dependence of Round Type Electrodeless Lamp According to Ferrite Core and Cold Spot Temperature
Authors 김남군(Kim, Nam-Goon) ; 양종경(Yang, Jong-Kyung) ; 이종찬(Lee, Jong-Chan) ; 한후석(Han, Hoo-Sek) ; 박지식(Park, Jee-Sik) ; 박대희(Park, Dae-Hee)
Page pp.833-838
ISSN 1975-8359
Keywords ICP ; Electrodeless lamp ; ferrite core ; amalgam
Abstract Generally Lighting system consists of lamp and luminaire. When a fluorescent lamp is installed in luminaire, power and light output is changed by ambient temperature. Particularly electrodeless lamp depends on the changes that are mercury pressure with amalgam temperature and magnetic properties with ferrite temperature. It has finally influence on optical efficiency. In this study, the temperature change of ferrite and cold spot, vessel are measured at transitional state and then same characteristics are measured with increase of ambient temperature. At transitional state, luminous flux is related to temperature change of cold spot that compare with behavior of mercury pressure and light output. At increase of ambient temperature, we analyzed change that efficiency and electrical, optical characteristics of elecrodeless lamp are related to ferrite core and cold spot temperature. Additionally, spectrum, color temperature and coordination are measured to check that is relation with ambient temperature.