• 대한전기학회
Mobile QR Code QR CODE : The Transactions of the Korean Institute of Electrical Engineers
  • COPE
  • kcse
  • 한국과학기술단체총연합회
  • 한국학술지인용색인
  • Scopus
  • crossref
  • orcid
Title Study on the Address Discharge Characteristics for the Improvement of the Mis-firing Problem in AC PDP
Authors 전원재(Jeon, Won-Jae) ; 김동훈(Kim, Dong-Hun) ; 이석현(Lee, Seok-Hyun)
Page pp.1151-1156
ISSN 1975-8359
Keywords PDP ; Address discharge ; Wall charge ; Misfiring
Abstract Unstable sustain discharges can occur at the bottom cells of the panel at high temperature. To solve this problem, the wall charge variation during an address period was investigated. A test panel of 7.5 inch XGA level was used and one green cell was measured. In order to realize operating condition equal to that of the bottom cells of 50 inch panel, the addressing stress pulses are applied. It seems that the resultant wall charge loss during address period increased with increase of stress time, temperature, pressure and Xe %. Wall charge loss increases with potential difference between scan electrode and address electrode, therefore wall charge loss can be minimized by the increase of scan voltage during address period.