Title Fault Tolerance Improvement of IPM Type BLDC Motor Considering Winding Configuration under a Stator Inter-Turn Fault Condition
Authors 김희운(Kim, Hee-Woon) ; 윤진규(Yoon, Jin-Gyu) ; 허진(Hur, Jin)
DOI https://doi.org/10.5370/KIEE.2011.60.3.524
Page pp.524-530
ISSN 1975-8359
Keywords Stator turn fault ; IPM motor ; Winding configuration ; Magneto-Motive Force (MMF) ; Harmonic component ; input current ; Generated torque
Abstract This paper analyzes fault tolerance under a stator turn fault, according to the winding configuration. Improvement of torque characteristics and fault tolerance can be achieved by winding configuration without additional methods. And, torque characteristics and fault tolerance according to the winding configuration can be usually analyzed by analytical method. But, when the stator turn fault generates, compare to the steady-state, analysis of torque characteristics and fault tolerance using the analytical method is not accurate because it does not reflect influence in mutual inductance and magnetic non-linearity. Therefore, analysis of torque characteristics and fault tolerance has to be performed by using the numerical method under fault condition. This paper develops fault characteristics according to the winding configuration using the FEM-base model considered magnetic non-linearity. And, this paper suggests fault tolerance improvement according to the winding configuration, by the comparison of 8/12 and 10/12 models, under fault condition.