• 대한전기학회
Mobile QR Code QR CODE : The Transactions of the Korean Institute of Electrical Engineers
  • COPE
  • kcse
  • 한국과학기술단체총연합회
  • 한국학술지인용색인
  • Scopus
  • crossref
  • orcid
Title The Characteristic of Data Transmission for Power Line Communication using an AC Arrester for Electric Railway
Authors 김재문(Kim, Jae-Moon) ; 안승호(Ahn, Seung-Ho) ; 김양수(Kim, Yang-Su) ; 김철수(Kim, Chul-Su)
DOI https://doi.org/10.5370/KIEE.2012.61.3.497
Page pp.497-502
ISSN 1975-8359
Keywords Power line communication ; Capacitive signal coupler ; AC arrester ; Attenuation ; Messenger wire
Abstract Power line communication(PLC) is a kind of communication technology, was made use of controling a frequency narrow band, but as the PLC technology developing, in the near future get to the commercial step that is broadband PLC upto 30 MHz. This paper deals with the PLC of electric railway using capacitive signal coupler. An AC arrester for catenary is used as a capacitive signal coupler, has the characteristic of capacitor. As a result of field test, a messenger wire used PLC contain much of conducted noise about overall frequency band and also signal attenuation rate increased with increasing frequency between two points. and the communication speed of PLC used messenger wire is 793kbps at a distance of 40m. Experimental results show the possibility of PLC using a messenger wire and an AC arrester for catenary at electric railway.