• 대한전기학회
Mobile QR Code QR CODE : The Transactions of the Korean Institute of Electrical Engineers
  • COPE
  • kcse
  • 한국과학기술단체총연합회
  • 한국학술지인용색인
  • Scopus
  • crossref
  • orcid
Title Implement of Dynamic Performance Measurement System Between Pantograph and Contact wire in Tunnel
Authors 박영(Park, Young) ; 박철민(Park, Chul-Min) ; 이기원(Lee, Ki-Won) ; 권삼영(Kwon, Sam-Young)
DOI https://doi.org/10.5370/KIEE.2012.61.11.1732
Page pp.1732-1736
ISSN 1975-8359
Keywords Uplift of contact wire ; Catenary system ; Condition monitoring system
Abstract To increase speed up of train, in the field of catenary system, it is necessary to develop of new monitoring methods for dynamic interaction between pantograph and contact wire. Also, there is a need to develop technologies that constantly measure are from various railway structure such as uplift of contact wire, vibration of catenary, dynamic strain of contact line in tunnel. In this paper condition monitoring systems for dynamic performance of catenary systems in tunnel were proposed. An advanced method and results of field tests using high speed camera for monitoring of vertical upward movement of the grooved contact wire due to the force produced from the pantograph were presented. The proposed uplift measurement system of contact wire is expected to enhance precision of current collection quality performance assessment methods at high-speed lines.