Title A Study on Transient Analysis of Linear Induction Motor with Ununiform Airgap for Shallow-depth Underground Train
Authors 이형우(Lee, Hyung-Woo) ; 박찬배(Park, Chan-Bae) ; 원성홍(Won, Sunghong)
DOI https://doi.org/10.5370/KIEE.2013.62.5.723
Page pp.723-729
ISSN 1975-8359
Keywords Equivalent linear rotating model ; Linear induction motor ; LIM ; Shallow-depth underground train ; Ununiform airgap
Abstract This paper presents an parallel type Linear Induction Motor with ununiform airgap for a shallow-depth underground train with 100‰ grade and 15 m curvature. This parallel type LIM has enough gradability but has inherently ununiform airgap between center and end parts. Consequently, performance when the train passes curved section should be considered with transient analysis. Moreover, general parallel operation, 1C2M which is usually used for train operation, deteriorates LIM performance because of different line velocity between inner and outer LIMs. Transient analysis has many problems such as huge model, lots of meshes, very long calculation time, truncation error and so on. This paper has presented a novel technique using equivalent linear rotating model in order to solve these problems and has analyzed parallel type LIM by using the proposed technique. Finally, LIM performance according to independent operating control has been investigated.