Title A Study on Implementation of a Transient Radiation Effects on Electronics(TREE) Assessment System Based on M&S
Authors 이남호(Lee, Nam-Ho) ; 이승민(Lee, Seung-Min)
DOI https://doi.org/10.5370/KIEE.2013.62.7.969
Page pp.969-973
ISSN 1975-8359
Keywords Pulse radiation ; Damage effect ; Assessment system ; Analysis model ; Gamma-radiation ; Dose rate
Abstract To simulate the effect of high dose-rate radiation on semiconductor devices, device modeling work has been performed especially in the area of photo-current generation by a PIN diode. The resultant analytical values were compared with experimental ones that were specially designed and performed to benchmark the simulation results. Initial results showed 27.85% error between the simulation and the experiment. The error can be further reduced by improvement both in simulation and in related experiments. The developed technique from the study can be applicable to radiation dosimetry and to analysis on the radiation effects in electronics.