Title Improved back-EMF of 30kW Interior Permanent Magnet Synchronous Generator for Small Hydropower Generation
Authors 김대경(Kim, Daekyong) ; 정학균(Jeong, Hak-Gyun) ; 박한석(Park, Han-Seok)
DOI https://doi.org/10.5370/KIEE.2014.63.5.660
Page pp.660-665
ISSN 1975-8359
Keywords Back-EMF ; Cogging torque ; Notch ; Small hydropower generator
Abstract This paper presents the improved back-EMF of Interior Permanent Magnet Synchronous Generator(IPMSM) for small hydropower generator. To improve back-EMF characteristics, the size and position of notch are applied to the rotor. In addition, parametric analysis of the notch size and position was performed. Finally, the back-EMF characteristic analysis are confirmed by the experimental results.