• 대한전기학회
Mobile QR Code QR CODE : The Transactions of the Korean Institute of Electrical Engineers
  • COPE
  • kcse
  • 한국과학기술단체총연합회
  • 한국학술지인용색인
  • Scopus
  • crossref
  • orcid
Title Implementation of the Real-time Measurement System of Receiver Sensitivity for a Laser Range Finder
Authors 이영주(Lee, Young-Ju)
DOI https://doi.org/10.5370/KIEE.2016.65.1.108
Page pp.108-111
ISSN 1975-8359
Keywords LRF ; Sensitivity ; Optical receiver ; MDS
Abstract We propose the method for measuring sensitivity of optical receiver of a long-range laser range finder in real-time. The sensitivity of the detector can be calculated using the detected voltage of the reference sensor, the area of the reference sensor and the transmittance ratio of neutral density filters. To evaluate the performance of the proposed method, we implemented a system and performed experiments. As a result, this system can be measured from 2nW to 113μW. With this system, we measured the sensitivity of 37nW and 7nW with PIN PD and APD sample, respectively. This system has the advantage for the performance test of an optical sensor module in the long-range laser range finder.