Title Analysis on Installation Condition According to Dynamic Characteristics for Overhead Catenary System
Authors 박영(Park, Young) ; 이기원(Lee, Kiwon)
DOI https://doi.org/10.5370/KIEE.2016.65.9.1605
Page pp.1605-1609
ISSN 1975-8359
Keywords Overhead catenary system ; duration of an arc ; Current collection system.
Abstract The measurement of current collection performance between pantograph and contact wire of overhead catenary system is intended to prove the safety of operation and the quality of the current collection system. The results of interaction performance of current collection system are required for approving with commercial operation on railway lines. The methods of interaction performance of current collection system are defined on interactional standards such as IEC 62486 and EN 50317. In this paper, the interaction performance is evaluated by the percentage of arcing on Honam high-speed line and the results are used for adjustment of the overhead catenary line structure. The experimental results in Honam high-speed line confirm that the duration of an arc lasting longer 25 ms between pantograph and contact wire was depended on the conditions of overhead contact line after installation.