• 대한전기학회
Mobile QR Code QR CODE : The Transactions of the Korean Institute of Electrical Engineers
  • COPE
  • kcse
  • 한국과학기술단체총연합회
  • 한국학술지인용색인
  • Scopus
  • crossref
  • orcid
Title The Characterization of Electrolytic Ion Water Generator by Electrode
Authors 한병조(Han, Byung-Jo) ; 이연(Lee, Yeon) ; 류봉조(Ryu, Bong-Jo) ; 구경완(Koo, Kyung-Wan)
DOI https://doi.org/10.5370/KIEE.2016.65.10.1786
Page pp.1786-1791
ISSN 1975-8359
Keywords Electrolytic ion water generator ; Mesh electrode ; Flow path electrode
Abstract The damage has occurred inside the semiconductor pattern When using conventional wet station for semiconductor. It was used for electrolytic ion water generator in order to prevent damage to the semiconductor pattern. It was designed and developed a flow path electrode and the mesh electrode to check the efficiency of the electrode. And It confirmed the expected results through the simulation of the flow path. and ORP were measured in accordance with the current and voltage of mesh electrode and flow paht electrodes. Flow path electrode 22A is 3V, up to pH 9.8, the value of ORP-558mV was measured and the mesh electrode was measured up to pH 9.8, ORP -350mV.