Title A Study on a Sensitivity Analysis of Design Parameters for the Speed-up of Overhead Rigid Conductor System
Authors 이기원(Lee, Kiwon) ; 조용현(Cho, Yong Hyeon) ; 권삼영(Kwon, Sam-Young) ; 박영(Park, Young)
DOI https://doi.org/10.5370/KIEE.2017.66.2.453
Page pp.453-458
ISSN 1975-8359
Keywords Rigid conductor ; R-Bar ; Overhead line ; Speed-up
Abstract R-Bar (Overhead Rigid Conductor system) has been lately used for the speed of over 200km/h in Europe, while it has been developed and used for the max. speed of 120km/h in Korea. Because R-Bar has advantages of reduction of tunnel cross sectional area and maintenance, its development for more high-speed is urgent in Korea having many mountain area. Therefore a sensitivity analysis of design parameters for the speed-up of R-Bar has performed in this study. For the analysis, we have developed a program for the prediction of dynamic characteristics between a pantograph and R-Bar. The program was evaluated with the actual test result and a current collection performance according to the parameters such as a distance between brackets, a stiffness of bracket and of R-Bar rail was predicted with the program.