• 대한전기학회
Mobile QR Code QR CODE : The Transactions of the Korean Institute of Electrical Engineers
  • COPE
  • kcse
  • 한국과학기술단체총연합회
  • 한국학술지인용색인
  • Scopus
  • crossref
  • orcid
Title Analysis on the Method of Forward-Reverse Fault localization of Electric Railways for the Improvement of Accuracy
Authors 김명수(Myeong Su-Kim) ; 김성철(Seong Cheol-Kim)
DOI http://doi.org/10.5370/KIEE.2018.67.12.1735
Page pp.1735-1742
ISSN 1975-8359
Keywords Fault localization ; Grounding test ; Transitive phenomenon ; Feeding ; booster
Abstract The number of electric railway failures will increase due to the external and internal effects of electric railroads. The grounding test with 25,000V is to artificially test the transmission voltage to ground, and it is possible to cause risks of electric shock and other equipment insulation damage in neighboring enclosure. In 2016, method of fault localization changed to low - voltage at 380V from artificially high- voltage in the grounding tests since opening of Seoul Metropolitan Express Railway; The method is more accurate and safer rather than the previous one because it gets more data from unlimited grounding tests. However, an electric current falls on the track section where the track branches and vehicle bases with many lines. To precisely detect a transitive phenomenon, it is necessary to continuously study and additionally install.