• 대한전기학회
Mobile QR Code QR CODE : The Transactions of the Korean Institute of Electrical Engineers
  • COPE
  • kcse
  • 한국과학기술단체총연합회
  • 한국학술지인용색인
  • Scopus
  • crossref
  • orcid
Title Fault Tolerance Controls of a Three-leg Two-phase Inverter to Secure Functional Reliability for Heated Windshield in xEV
Authors 정기헌(Gi-Heon Jeong) ; 이형우(Hyung-Woo Lee) ; 이교범(Kyo-Beum Lee)
DOI https://doi.org/10.5370/KIEE.2023.72.7.829
Page pp.829-835
ISSN 1975-8359
Keywords Fault tolerance; Fault control; Switch open fault; Inverter reliability; Funtional reliability; xEV Inverter
Abstract This paper proposes a fault tolerance control method for a three-leg two-phase inverter to secure the functional reliability of xEV components. It diagnoses an open-switch fault with the size of the current sensed within 2 cycles in real time without applying conventional coordinate conversion and complex formulas. The MOSFET that has failed stops operating, and another MOSFET in the same leg are set to always conduct. In the three-leg two-phase inverter, the fault state is classified for each case in which an open-switch fault diagnosis has occurred, and the duty ratio of the A, B, and C phases is adjusted. Through duty ratio adjustment and phase shift control for each switch of the inverter, functional reliability is secured by supplying the same power as before the failure. The functional reliability of an inverter is verified through simulations and experimental result.