Title |
Characteristic of Three-Phase Voltage Type Soft-Switching Inverter using the Novel Active Auxiliary Resonant DC Link Snubber |
Authors |
성치호(Sung, Chi-Ho) ; 허영환(Heo, Young-Hwan) ; 문상필(Mun, Sang-Pil) ; 박한석(Park, Han-Seok) |
DOI |
https://doi.org/10.5370/KIEEP.2016.65.2.114 |
Keywords |
Instant space vector PWM ; Zero current soft switching ; Electro Magnetic Interference ; Active auxiliary resonance ; Voltage surge and current surge |
Abstract |
This paper is Instant space vector PWM(Pulse Width Modulation)power conversion devices in switching power semiconductors from my generation to losses and switching when the voltage surge and current surge of electronic noise(EMI: Electro Magnetic Interference / RFI: Radio Frequency Interference)to effectively minimize the power soft-switching power conversion circuit topologies of auxiliary resonant DC tank for the purpose of high performance realization of the electric power conversion system by the high-speed switching of a semiconductor device(AQRDCT simultaneously : an active auxiliary resonance using auxiliary Quasi-resonant DC tank)DC link snubber switch has adopted a three-phase voltage inverter. AQRDCL proposed in this paper can reduce the effective and current peak stress of the power semiconductors of the auxiliary resonant snubber circuit compared to the conventional active-resonant DC link snubber, it is not necessary to install the clamp switch of the auxiliary resonant DC link, DC the peak current and power loss of the bus line can be reduced. |