Mobile QR Code QR CODE : Korean Journal of Air-Conditioning and Refrigeration Engineering
Korean Journal of Air-Conditioning and Refrigeration Engineering

Korean Journal of Air-Conditioning and Refrigeration Engineering

ISO Journal TitleKorean J. Air-Cond. Refrig. Eng.
  • Open Access, Monthly
Open Access Monthly
  • ISSN : 1229-6422 (Print)
  • ISSN : 2465-7611 (Online)
Title A Study on Energy Distributions Produced by Dish Solar Concentrating System
Authors 현성택 ; 강용혁 ; 천원기
Page pp.907-913
ISSN 12296422
Keywords Flux distribution ; 플럭스 분포 ; Dish solar concentrating system ; 접시형 태양열 집광 시스템 ; Reflector ; 반사경 ; Absorber ; 흡수기
Abstract An experimental study on energy density distributions produced by dish solar concentrating system was performed to optimally design and rightly position a cavity receiver. This deemed also very useful to find and correct various errors associated with a concentrator. It is observed that the actual focal length is 2.17m with a maximum energy density of 1.89MW/m2. By evaluating the position of flux centroid, it was found that there are errors within 2cm from the target center. As a result of the percent power within radius, approximately 90% of the incident radiation is intercepted by about 0.06m radius. The area concentration ratio normalized to 800W/m2 insolation and 90% mirror reflectivity was 347 suns. The total integrated power of 2467W was measured under focal flux distributions, which corresponds to the intercept rate of 85.8%.