Title Modeling of the Safety Distance between Defrost Heater and Plastic Inner Wall of Refrigerator
Authors 정영 ; 신종민 ; Alexei V. Tikhonov
Page pp.196-202
ISSN 12296422
Keywords Defrost heat ; 제상 히터 ; Plastic inner wall ; 플라스틱 내벽 ; Safety distance ; 안전거리
Abstract Two dimensional modeling was carried out to find the safety distance between the defrost heater and the plastic inner wall of domestic refrigerator. Estimation was processed for the three cases; the estimation of plastic wall temperature (1) without any protection, (2) with an aluminum foil attached on a wall, and (3) with an aluminum shield installed between heater and wall. The former two cases are found to be dangerous during defrosting process, because the temperatures of inner wall reach above 80℃, which is the upper temperature limit of the wall material. The case with an aluminum shield is considered to be safe by maintaining the temperature of the wall in the range of 60℃ during defrosting process.