Title |
Effects of Charging Conditions on Evaporating Temperature for Diffusion Absorption Refrigerator |
Keywords |
Diffusion absorption refrigerator ; 확산형 흡수식 냉장고 ; Auxiliary gas ; 보조가스 ; Ammonia aqueous solution ; 암모니아 수용액 ; Charging concentration ; 충진농도 ; Solution charge ; 용액충진량 |
Abstract |
A diffusion absorption refrigerator is a heat-generated refrigeration system. It uses a three-component working fluid consisting of the refrigerant(ammonia), the absorbent (water) and the auxiliary gas(hydrogen or helium). In this study, experimental investigations have been carried out to examine the effects of charging conditions of working fluids on the evaporating temperature for diffusion absorption refrigerator. Experimental parameters considered in the present experiments are charging concentration, solution charge and system pressure determined by auxiliary gas charged. As a result, in the charging condition of 35% of concentration and 20kgf/cm2 of system pressure, the system has the lowest evaporating temperature. It was found that there exists a minimum value of solution charge for the operation of diffusion absorption refrigerator. |