Title A Theoretical Analysis on the Factors Affecting the Operation of Loop Heat Pipe
Authors 이기우 ; 전원표 ; 이욱현 ; 박기호
Page pp.1107-1116
ISSN 12296422
Keywords Sintered wick ; 소결윅 ; Wick porosity ; 윅기공률 ; Pressure drop ; 압력손실 ; Vapor line ; 증기관 ; Liquid line ; 액체관 ; Compensation chamber ; 보상실
Abstract In this paper, the effects of diverse parameters on the operation of loop heat pipe(LHP), such as particle diameter of sintered porous wick, wick porosity, vapor line diameter, thickness of wick and heating capacity were investigated by a theoretical analysis. A LHP has a wick only in its evaporator for the circulation of working fluid, and utilizes a porous wick structure of which pore size is very small to obtain a large capillary force. The working fluid is water and the material of sintered porous wick is copper. For these different parameters, capillary pressure, pressure drop in wick, pressure drops and temperature distribution were analyzed by a theoretical design method of LHP.