Title |
Heat Transfer Performance of Evaporator Used in a Domestic Refrigerator/Freezer Under Frosting Condition |
Keywords |
Heat transfer ; 열전달 ; Discrete flat plate fin-and-tube type ; 단속 평판 휜관형 ; Continuous flat plate fin-and-tube type ; 연속 평판 휜관형 ; Spine fin-and-tube type ; 침상 휜관형 ; Frosting ; 착상 |
Abstract |
In this study, the air-side heat transfer coefficients of several types of evaporators in the household freezer/refrigerators are investigated. The types considered in this work are: discrete flat plate fin-and-tube type(in-lined tube array), continuous flat plate fin-and-tube type(staggered tube array), and spine fin-and-tube type(in-lined tube array). The heat transfer correlations obtained from this study for each heat exchangers could expect heat transfer coefficients less than 5% of errors. The result indicates that the air-side heat transfer performance of spine fin-and-tube type evaporator shows the highest value under dry conditions, but discrete flat plate fin-and-tube type evaporator shows the highest value among these three evaporators under frosting conditions. |