Numerical and Experimental Analysis of Design Parameters of a Slim Room Air-conditioner |
Authors |
신종진 ; 이희술 ; 김종문 ; 민준기 ; 오상경 |
Keywords |
Slim air-conditioner ; 슬림형 에어컨 ; Turbo fan ; 터보팬 ; Scroll ; 스크롤 ; Bell mouth ; 벨마우스 ; Front panel ; 전면 패널 ; Sound pressure level ; 소음레벨 |
Abstract |
Numerical simulations and experiments were conducted to analyze the design parameters for a slim room air-conditioner. These design parameters included a fan shape, a front panel, a scroll shape, a bell mouth, a distance between a fan and a heat exchanger, etc. Each design parameter was analyzed numerically and / or experimentally in terms of the flow rate and the sound pressure level, which should be the most influential factors for developing the slim room air-conditioner. The fan with a uniform height showed a better performance than that with a linearly varying height. It is recommended to use a front grill rather than a front panel according to sound pressure levels since the front panel itself is a huge resistance to the inlet flow. A redesigned scroll shape by changing the rotational direction of a fan also contributed a lot to lowering the sound pressure level. There existed a distance between a fan and a heat exchanger, where flow rates increased effectively. |