Title |
Horizontal Air-Jet Effect on the Natural Convection around a Range-Hood System |
Keywords |
Horizontal air-jet ; 수평 급기 ; Natural convection ; 자연대류 ; Contaminated air ; 오염된 공기 ; Optimal velocity ; 최적속도 |
Abstract |
Horizontal air-jet effect has been utilized in some air conditioning systems in order to control the contaminated air indoor. In the present study, the flow and heat transfer of the contaminated air from a range hood system has been investigated with or without horizontal air-jet effect when the hood fan is on or off. For the present numerical experiment, PAT Flow code has been used. From the present numerical simulations, it has been shown that the air jet of a range hood generates coanda effect confining the contaminated air in a certain region. Furthermore, the qualitative relation between the flow rate of the capture air jet and the distribution pattern of the contamination has been discussed. |