Title |
The Proposal of a New Drainage System without Incline of Piping and Experiment on Drainage Flow Characteristics |
Keywords |
New drainage system ; 신배수시스템 ; Siphonage ; 사이펀 작용 ; Underfloor piping system ; 바닥배관방식 |
Abstract |
In Korea, pumping pipe using gravity way by water is most popular method in drainage system. But, it is difficult to repair a drainpipe in this method because the drain pipe diameter is increased as using this method. In this research, we propose a new drainage system. The system aim for an adaptedness with buildings, freedom of plan, construction and renewal in water pipe equipments, etc. The new system is not need of incline of piping, and it uses drainage power that is changed potential energy by high velocity flow as making Siphonage at vertical pipe. Therefore, the diameter of piping can decreased than existing piping system established in the ceiling. Also because connecting position will be located at the lower part, it is changed the potential energy of drainage to the high velocity flow. In addition, drainage will be smooth because the fixture drain is linked by each drain pipes. |