Title The Study on the Improvement of Ventilation Performance in the Soundproof Tunnel
Authors 이경희 ; 조성우 ; 최정민 ; 김경환 ; 박창섭
Page pp.922-929
ISSN 12296422
Keywords 방음터널 ; 자연환기 ; 매연규제 ; 교통 환기력 ; 전산유체프로그램 Sound roof tunnel ; Natural ventilation ; Emission control ; Ventilation by vehicle ; CFD
Abstract This paper compared ventilation performance between the sound roof tunnel with flat roof and the sound roof tunnel with gable roof. The ventilation rate of the sound roof tunnel is calculated by natural ventilation rate plus ventilation by vehicle. The roof type is divided by the shape of the roof and the ventilator location on the roof. The results between calculation and CFD on the ventilation rate are almost alike. The ventilation rate on the flat roof is 558.4m3/s with mid-ventilator and 496.8m3/s with left-right ventilator. The ventilation rate on the gable roof is 653.2m3/s with mid-ventilator and 611.6m3/s with left- right ventilator. The ventilation rate of soundproof with gable roof is higher than that with flat roof. The ventilation rate and with mid-ventilator is higher than that with left-right ventilator the soundproof roof. Therefore, the ventilation performance of soundproof roof depends on the roof shape and ventilator location on the roof.