Title A Study on the Development of High-rise Curtain Wall Thermal Analysis Program
Authors 노상태(Sang-Tae No) ; 김강수(Kang-Soo Kim) ; 정진세(Jin-Se Chung)
Page pp.10-18
ISSN 1229-6422
Keywords 초고층건물 ; 커튼월 ; 열전도 ; 유한체적법 ; 열관류율 High-rise building ; Curtain wall ; Heat conduction ; Finite volume method ; U-factor
Abstract The purpose of this study is to develop an user-friendly computer program which can analyze the thermal performance of high-rise curtain wall. In this study, the sub-routines for FVM SOLVER, HIGH-RISE CONDITION CALCULATION, AUTOMATIC SPECIFICATION BOUNDARY/MESH, MATERIAL DATABASE, and GRAPHICAL CONDENSATION/U-FACTOR OUTPUT were developed by using Visual Basic. The curtain wall heat conduction simulation results of program showed good agreement with those of FLUENT and THERM. The minimum and maximum relative error rates were 3.17 and 9.68% compared to other software.