Title |
Study on the Comparison of Heat Exchange Performance of Liquefied Gas Vaporizer at Super Low Temperature |
Authors |
김필환(Pil-Hwan Kim) ; 김철표(Chul-Pyo Kim) ; 정효민(Hyo-Min Jeong) ; 정한식(Han-Shik Chung) ; 이용훈(Yong-Hun Lee) |
Keywords |
핀 ; 액화질소 ; 액화가스 ; 초저온 ; 기화기 Fin ; LN2 ; Liquified gas ; Super low temperature ; Vaporizer |
Abstract |
Air-heating vaporizer usually is used to regasify LNG at satellite areas because of the small demand of natural gas there. The common type of air heating vaporizer which exists in the market is the longitudinally finned type with 8 fins, 55mm fin length and 2mm fin thickness. To contribute in developing an efficient air-heating vaporizer, experiment on finned type air-heating vaporizer using 8 fins, 50mm(fin length) with 2mm(fin thickness) which exist in the market and 4 fins, 75mm(fin length) with 2mm(fin thickness), which is proposed, were conducted. Then, both types of vaporizers are compared. The experiments were conducted in one hour by varying the ambient condition and the length of the vaporizer. The ambient air was controlled so that it has the same temperature, humidity and air velocity with air condition in every season available and the length was varied 4000mm, 6000mm and 8000mm for each type of vaporizer. Additional experiment with longer duration, i.e. In this experiment, the main aspects in analyzing the characteristics of the air heating vaporizer the inlet-outlet enthalpy difference and the outlet temperature of the working fluid. LN2 is used to substitute LNG because of safety reason. The results show that the characteristics of the finned type 4fin75le vaporizer are comparable to finned type 8fin50le vaporizer. |