Title A Study on the Performance Evaluation of the Hybrid Ventilation System for Small Apartment Houses
Authors 전주영(Chu-Young Chun) ; 김길태(Gil-Tae Kim) ; 이종성(Jong-Sung Lee) ; 김상희(Sang-Hee Kim)
Page pp.696-701
ISSN 1229-6422
Keywords 하이브리드환기 ; 환기효율 Hybrid ventilation ; Ventilation effectiveness
Abstract From Feb. 2006, the ventilating systems with air exchange rate of over 0.7times/ hour are installed at the apartment houses (over 100 units). Installation cost and maintenance cost are very important factors for ventilating system because consumers have to pay the expenses of that system. Especially small apartment needs more considerations because small apartment is comparatively the economically weak part. The purpose of this study is to the performance evaluation of the hybrid ventilation system for small apartment houses. Hybrid system 1 consists of natural ventilation system and duct type exhaust diffusers. Hybrid system 2 has natural ventilation system and toilet exhaust system with static pressure fan. Infiltration of test apartment houses with ventilation system is under 0.1 times/hour. Mean air age of hybrid system 1 is 1.52 hours and hybrid system 2 is 1.42 hours. Mean ventilation effectiveness of hybrid system 2(93%) is higher than that of hybrid system 1(81%).