Title |
An Experimental Study on the Performance Characteristics of a Multi Type Refrigerator Using R600a |
Authors |
안지훈(Jihoon Ahn) ; 장용희(Yonghee Jang) ; 김용찬(Yongchan Kim) ; 최원섭(Wonseop Choi) ; 오승환(Seungwhan Oh) ; 김창년(Changnyeun Kim) ; 이재승(Jaeseung Lee) |
Keywords |
멀티 ; 이소부탄 ; 가변속 ; 냉장고 ; 성능 Multi ; R600a ; Variable speed ; Refrigerator ; Performance |
Abstract |
Various types of refrigerators become popular in the market such as a common refrigerator, kimchi refrigerator and wine cellar. It is required to develop a multi type refrigerator combining these refrigerators to save space and energy consumption. In this study, the performance of a multi type refrigerator, which consists of one machine room and three evaporators, was measured in a bench type multi refrigerator. The multi type refrigerator was tested by varying the number of refrigerator cabinet, refrigerant charge, and temperature conditions. In addition, the multi type refrigerator with a suction line heat exchanger(SLHX) was tested to improve system performance. Based on the experimental data, the multi type refrigerator showed better performance than the conventional refrigerator(single type system). Besides, the COP of the single system increased from 1.0 to 1.37, and those of the dual and triple system increased from 1.29 to 1.39, and 1.22 to 1.51, respectively, by applying the SLHX. |