Mobile QR Code QR CODE : Korean Journal of Air-Conditioning and Refrigeration Engineering
Korean Journal of Air-Conditioning and Refrigeration Engineering

Korean Journal of Air-Conditioning and Refrigeration Engineering

ISO Journal TitleKorean J. Air-Cond. Refrig. Eng.
  • Open Access, Monthly
Open Access Monthly
  • ISSN : 1229-6422 (Print)
  • ISSN : 2465-7611 (Online)
Title An Experimental Study on the Optimization of the Performance Characteristics of a Refrigeration System Using R-600a and R-134a
Authors 장의성(Euisung Jang) ; 윤원재(Wonjae Yoon) ; 정현준(Hyunjoon Chung) ; 정해원(Haewon Jung) ; 김용찬(Yongchan Kim)
Page pp.268-274
ISSN 1229-6422
Keywords 가정용 냉장고 ; 이소부탄 ; R-134a ; 성능계수 Household refrigerator ; R-600a ; R-134a ; COP
Abstract Because both R-134a and R-600a are used as a refrigerant of a household refrigerator in the global market, the home-appliance industry needs an optimized cycle for both refrigerants. The objective of this study is to provide the design guideline on the optimization of a refrigeration system using both refrigerants. For both refrigerants, the performance characteristics of the refrigeration system were tested by varying refrigerant charge amount, capillary tube length, suction diameter and SLHX length. The tested refrigeration system was optimized at the refrigerant charge of 60g and the capillary tube length of 3600㎜ with R-134a, and the refrigerant charge of 34g and the capillary tube length of 3900㎜ with R-600a. The COP increased from 1.63 to 1.68 for R-134a and increased from 1.37 to 1.48 for R-600a, respectively, by applying the suction diameter expansion. In addition, the COP of the R-134a and R-600a system decreased by 2.3∼2.4% as the SLHX length decreased by 300㎜.