Title Study on the Performance Characteristics of the Solar Hybrid System with Heat Pump Operating Temperature during Winter Season
Authors 김원석(Won-Seok Kim) ; 조홍현(Honghyun Cho)
Page pp.821-827
ISSN 1229-6422
Keywords 태양열시스템 ; 열펌프 작동온도 ; 작동시간 ; 태양열 의존율 Solar heating system ; Heat pump operating temperature ; Operating hour ; Solar fraction
Abstract Study on the performance characteristics of the solar hybrid system with heat pump operating temperature during winter season has performed by using an experimental test. The system performance and operating characteristics with the heat pump operating temperature, hour and load condition were investigated and analyzed. As a result, the hot water temperature was significantly affected by the heat pump operating temperature at the morning(time 1) and noon(time 2). However, hot water temperature was set by the radiation quality and collecting operation hour at the afternoon(time 3). In addition to the solar fraction was decreased for the high heat pump operating temperature because the heat pump operated with a long operating time and short operating period.