A Study on Relationship Insulation Thickness and Infiltration Load by Window |
Authors |
최정민(Jeong-Min Choi) ; 조성우(Sung-Woo Cho) |
DOI |
http://dx.doi.org/10.6110/KJACR.2012.24.5.422 |
Keywords |
창틀 ; 침기 ; 단열재 두께 ; 부하 ; 상쇄효과 Window frame ; Infiltration ; Insulation thickness ; Load ; Compensation effect |
Abstract |
This study investigates on the relationship between total load which is caused by infiltration and insulation thickness against compensation effect. As the result of experiment, the PVC(Synthetic resins sash) window frame in airtightness is superior to the AL(Aluminum sash) window frame. In this study, as the increasing of insulation thickness in reference building does not reduce significantly cooling load, the compensation effect due to airtightness against infiltration is very small. But the compensation effect against infiltration can be closely related with heating load. Therefore, the proper thermal insulation thickness can be needed respect to cooling and heating load. |