Title |
Study on the Performance Improvement for an Automobile Air Conditioning System Using Alternative Refrigerant R1234yf |
Authors |
조홍현(Honghyun Cho) ; 이호성(Hoseong Lee) ; 박차식(Chasik Park) |
DOI |
http://dx.doi.org/10.6110/KJACR.2013.25.4.201 |
Keywords |
대체냉매 ; R1234yf ; 지구온난화지수 ; 내부열교환기 ; 성능계수 Alternative refrigerant ; R1234yf ; GWP ; Internal heat exchanger ; COP |
Abstract |
The performance of automobile air conditioning systems of R1234yf was evaluated and compared with that of R134a. In particular, the performance evaluation was carried out by installing an internal heat exchanger in order to improve the performance of the system used in R1234yf. A performance comparison between the R1234yf and R134a for automotive air conditioning revealed that the cooling capacity and COP of the 1234yf system without the IHX decreased by up to 7% and 4.5%, respectively, but those with the IHX decreased by up to 1.8% and 2.9%, respectively. |