Title |
Correlation Analysis Between Fenestration Energy Consumption Efficiency Rating System and Building Energy Consumption |
Authors |
곽희정(Hee-Jeong Kwak) ; 장향인(Hyang-In Jang) ; 이현수(Hyun-Soo Lee) ; 엄재용(Jae-Yong Eom) ; 서승직(Seung-Jik Suh) |
DOI |
http://dx.doi.org/10.6110/KJACR.2013.25.6.338 |
Keywords |
창호 에너지 소비 효율 등급제 ; 건물 에너지 ; 상관 분석 ; 열관류율 ; 기밀성 ; 일사열 취득 계수 Fenestration energy consumption efficiency rating system ; Building energy ; Correlation analysis ; U-value ; Air leakage ; SHGC ; |
Abstract |
The purpose of this study is to analyze the correlation between the ‘Fenestration Energy Consumption Efficiency Rating System’ (hereafter referred to as FECERS) and building energy consumption. ‘EnergyPlus’ was used for the calculation of energy consumption in apartments and office buildings, according to FECERS’s rating and SHGC. The result indicates that the FECERS has high correlation with apartments, but has low correlation with office buildings. Also, it indicates that office buildings have a large impact from SHGC, which is not reflected in the FECERS. Consequently, the FECERS needs to be improved, by adding optical properties to assessment items. Additional study is required to establish the fenestration rating system, which, on the basis of this work, has high relevance to building energy consumption. |