Mobile QR Code QR CODE : Korean Journal of Air-Conditioning and Refrigeration Engineering
Korean Journal of Air-Conditioning and Refrigeration Engineering

Korean Journal of Air-Conditioning and Refrigeration Engineering

ISO Journal TitleKorean J. Air-Cond. Refrig. Eng.
  • Open Access, Monthly
Open Access Monthly
  • ISSN : 1229-6422 (Print)
  • ISSN : 2465-7611 (Online)
Title Performance Analysis of an ORC System for Two Different Working Fluids
Authors 장홍순(Hong-Soon Chang) ; 송영길(Yeong-Kil Song) ; 한영섭(Young-Sub Han)
DOI http://dx.doi.org/10.6110/KJACR.2013.25.7.413
Page pp.413-417
ISSN 1229-6422
Keywords 유기랭킨싸이클 ; 작동유체 ; 구동 ; 발전기 ; 냉매 ; 냉매 Organic Rankine Cycle ; Working Fluid ; Permanence ; Power Generation ; R245fa ; R134a ;
Abstract The organic Rankine Cycle (ORC) uses a kind of refrigerant as a working fluid that evaporates at relatively low temperature, as the Rankine Cycle uses superheated steam as the working fluid. A small scale ORC test bench was installed, and two different working fluids (R245fa and R134a) were injected into the test bench. The test bench was in operation with the two different working fluids under the same conditions. The effects against the system performance from the different working fluids were analysed, and root causes were identified. Other factors reflecting the power generation efficiency were also found. A conclusion was drawn, that R245fa makes the system perform better, than R134a.