Mobile QR Code QR CODE : Korean Journal of Air-Conditioning and Refrigeration Engineering
Korean Journal of Air-Conditioning and Refrigeration Engineering

Korean Journal of Air-Conditioning and Refrigeration Engineering

ISO Journal TitleKorean J. Air-Cond. Refrig. Eng.
  • Open Access, Monthly
Open Access Monthly
  • ISSN : 1229-6422 (Print)
  • ISSN : 2465-7611 (Online)
Title The Condensation Risk Assessment of Vacuum Multi-Layer Glass and Triple Glass using the Temperature Difference Ratio
Authors 원종서(Jong-Seo Won) ; 남중우(Jung-Woo Nam)
DOI http://dx.doi.org/10.6110/KJACR.2013.25.11.573
Page pp.573-577
ISSN 1229-6422
Keywords 결로 ; 진공복층유리 ; 온도저하율 Condensation ; Vacuum multi-layer glass ; Temperature Different Ratio
Abstract An external window directly affects the energy performance of its building. In modern well-insulated buildings, U-values for walls of 0.36 W/㎡K or even lower can be realized. In such buildings, glazing with typical U-value of 2.1 W/㎡K or higher creates thermal weak spots on the facade. The performance of the existing triple glass window has been limited to energy savings and condensation prevention. In this study, the performance of condensation prevention of a vacuum multi-layer glass was analyzed. The final conclusion through mock-up experiments is as follows. The surface temperature of the vacuum multi-layer glass was 2℃ higher, and the temperature difference ratio (TDR) was 0.07 lower, than the corresponding values of the triple glass.