Title |
Study on Improvement of Air Quality through Analysis of Ventilation Efficiency in Complex Enclosures of a Ship |
Authors |
Jae-Hoon Jeong ; Doosam Song |
DOI |
http://dx.doi.org/10.6110/KJACR.2015.27.8.440 |
Keywords |
조선 ; 이중선저 ; 밀폐구역 ; 환기효율지표 ; 공기환경 Shipbuilding ; Double bottom ; Complex enclosure ; Scale for ventilation efficiency ; Air quality |
Abstract |
In the shipbuilding process, the confined work spaces of the ship are formed continuously; the ventilation method can therefore be limited to dilution ventilation due to the complex structure and limited opening of the confined space. Also, it is difficult to evaluate air-quality using measurement and an adequate ventilation method. CFD simulation methods are typically used in analyzing ventilation efficiency in these cases. In this study, a method is suggested to analyze the air quality of the complex enclosures in shipbuilding using CFD. Especially, among the conventional indices, the ventilation efficiency scales or indices, the supply air contribution (SVE4), and the age of the air (SVE3) (fit for the confined and complex enclosure) were applied. |