Title |
Effects of Coagulants and Ozone Concentration on the Livestock Manure Treatment Efficiency of AOF Process |
Authors |
Sung-Chol Jeong ; Rin Yun |
DOI |
http://dx.doi.org/10.6110/KJACR.2016.28.8.311 |
Keywords |
고도산화부상분리 공정 ; 응집제 ; 오존 농도 ; 분뇨처리 ; 수처리 AOF Process ; Coagulants ; Ozone concentration ; Livestock manure treatment ; Water treatment |
Abstract |
The efficiency of manure treatment was investigated in terms of the pH, BOD, COD, SS, T-N and TP with a variation in the injection amount of PAC, polymer and ozone. The wastewater flow rate to the AOF is of 7.4 ㎥/hr with a reaction time of 30 minutes. The amount of PAC and polymer changed by 30, 35, 40 ml/min, and 30, 40, 50 ml/min, respectively. The amount of ozone injected varied from 110, 125, and 150 kg-O3/hr. The optimum manure treatment performance was found for a PAC of 35 ml/min for the COD and SS, with polymer of 30 ml/min, and ozone injection of 150 kg-O3/hr. A substantially optimum dose for each PAC, polymer, and ozone was also found to exist. |