Title |
Application of Ventilated Cavity for Enhancing Insulation and Preventing Condensation of Curtain-wall System |
DOI |
https://doi.org/10.6110/KJACR.2017.29.1.021 |
Keywords |
통기성 중공층 ; 커튼월 ; 단열 ; 결로 ; 실물대 실험 Ventilated cavity ; Curtain-wall ; Thermal insulation ; Condensation ; Mock-up test |
Abstract |
Curtain-wall systems have been widely applied to buildings because of their lightweight and constructability characteristics. However, as curtain-wall systems include many building materials, vapor barriers can become damaged and condensation can occur. Due to the material properties of stone curtain-walls, the external appearance and structure of a building could be damaged and the insulating performance of the curtain-wall could be worse. Natural ventilation using an air cavity in a curtain-wall is expected to be effective for the prevention of condensation in inner walls and for the reduction of building cooling energy use in the summer. The purpose of this experimental study is to analyze the influence of a ventilated cavity on the insulating performance of a curtain-wall and the ventilated cavity depth and ratio of top opening needed to prevent condensation in a curtain-wall. |