Title |
A Study on Improvement According to Korea and China Evacuation Laws in Office Building |
Authors |
Byung-Hyun Lee ; Kyung-Hee Lee |
DOI |
https://doi.org/10.6110/KJACR.2017.29.2.051 |
Keywords |
오피스 빌딩 ; 피난관련 법 ; 복도폭 ; 전실 면적 ; 피난안전구역 Office building ; Evacuation laws ; Corridor width ; Ancillary room area ; Refuge safety area |
Abstract |
In the case of office buildings, domestic and Chinese evacuation laws were compared regarding the evacuation of horizontal and vertical buildings and evacuation to refuge safety areas. A simulation was conducted based on a refuge safety area in China. In the case of evacuating 1 floor, there was no significant difference in the flow of occupants to an ancillary room area in a domestic or Chinese building, but in China, the corridor width was narrower and the occupants have saw a long. In the case of evacuating 15 floors, the flow of occupants to an ancillary room area was different. In the case of China, it was possible for occupants to enter the ancillary room more quickly because the ancillary room area was wider than those found in domestic buildings, allowing quickly passage the ancillary room door. The results of this study found that if corridor width and ancillary room area were wider, evacuation times could be reduced. |