Title Working Fluid Selection and Performance Characteristics in an Organic Rankine Cycle for a Liquid Desiccant System
Authors Hye-Won Dong ; Jae-Weon Jeong
DOI https://doi.org/10.6110/KJACR.2020.32.2.058
Page pp.58-65
ISSN 1229-6422
Keywords 유기 랭킨 사이클; 작동유체; 액체식 제습시스템; 지역난방 Organic Rankine cycle; Working fluid; Liquid desiccant; District heating
Abstract The purpose of this study was to determine the working fluid of an organic rankine cycle (ORC), a combined heat and power system, for a liquid desiccant system using a district heat source wasted in the cooling season. Considering the environmental impact, R245fa, R514A, n-Pentane, R1233zd(E), and Nove649 have been considered and the thermodynamic analysis of all fluids were conducted. As a result, Novec649 was recommended because of high total net power and heat recovery rate in the condenser in terms of effectively applying the wasted district heat source. With Novec649 recommended in this study, the test bed for ORC system was built and it can provide more than 50°C of inlet desiccant solution in the regenerator of liquid desiccant system without an auxiliary heater.