Title Energy Analysis of the Heating and Cooling Load Estimation of a Small Hotel with an Integrated Rooftop Greenhouse
Authors Seok Min Choi ; Byung-Ju Lim ; Yu Whan Lee ; Kyu Hyung Do
DOI https://doi.org/10.6110/KJACR.2020.32.11.497
Page pp.497-509
ISSN 1229-6422
Keywords 건물에너지해석; 난방부하산정; 냉방부하산정; 건물통합형옥상온실 Building energy simulation; Heating load estimation; Cooling load estimation; Rooftop greenhouse integrated building
Abstract This study conducted a building energy simulation (BES) to compare the heating and cooling loads of a stand- alone greenhouse with a small hotel with an integrated rooftop greenhouse. The TRNSYS program was used to calculate the heating and cooling loads of the buildings. Numerical simulations were conducted for the stand-alone greenhouse model, a stand-alone small hotel model, and a small hotel with an integrated rooftop greenhouse model to compare the heating and cooling loads of each building. The results showed that the heating loads and total loads of the integrated model were reduced 20% and 15.7% than stand-alone model, respectively. Furthermore, if the temperature setting of the greenhouse was changed for different vegetables, the heating and cooling loads of the buildings varied. The setting temperature for high-temperature vegetables showed the largest energy reduction in the heating and cooling loads of the buildings. In conclusion, the integrated rooftop greenhouse had the advantage of energy reduction when it was installed on a conventional small hotel.