Mobile QR Code QR CODE : Korean Journal of Air-Conditioning and Refrigeration Engineering
Korean Journal of Air-Conditioning and Refrigeration Engineering

Korean Journal of Air-Conditioning and Refrigeration Engineering

ISO Journal TitleKorean J. Air-Cond. Refrig. Eng.
  • Open Access, Monthly
Open Access Monthly
  • ISSN : 1229-6422 (Print)
  • ISSN : 2465-7611 (Online)
Title Performance Analysis of a Small Diffusion Absorption Refrigerator based on Variations in Generator Heat Input
Authors Tae Hoon Woo ; Jun Hyun Nam ; Young Il Kim
DOI https://doi.org/10.6110/KJACR.2025.37.7.324
Page pp.324-331
ISSN 1229-6422
Keywords 성적계수; 확산형 흡수식 냉장고; 증발기; 재생기; 입열량; 자연 대류 COP; Diffusion absorption refrigerator; Evaporator; Generator; Heat input; Natural convection
Abstract This study examined the performance of a small diffusion absorption refrigerator (DAR) utilizing environmentally friendly refrigerants with variations in generator heat input. To mitigate ozone layer depletion primarily caused by halogenated refrigerants, organic refrigerants are gaining attention as environmentally sustainable alternatives. To evaluate performance, an experimental setup with a measurement system was constructed. A variable voltage generator was used to control the heating capacity of an electric heater supplying heat to the generator. Results indicated that the maximum coefficient of performance (COP) was achieved at a voltage of 180V and a power input of 51W. This outcome was attributed to characteristics of the two-phase flow regime in the bubble pump. Consequently, identifying optimal operating conditions is essential for maximizing efficiency of diffusion absorption refrigerators.