Title |
Numerical Analysis of Moisture Ventilation in the Dry Room |
Keywords |
Dry room ; 저습 공조실 ; Lithium ion battery ; 리튬 이온 전지 ; Scale of ventilation efficiency ; 환기효율 지수 ; Moisture contamination ; 수분오염 |
Abstract |
In this paper, the characteristics of moisture ventilation in the lithium ion battery manufacturing dry room are studied numerically using standardturbulence model. Both the steady-state and the unsteady behaviors of moisture ventilation are analyzed by considering local and uniform moisture generation. In order to evaluate the characteristics of moisture ventilation, three scales of ventilation efficiency and characteristic ventilation time are presented from the numerical results. It was shown that moisture distribution was dependent strongly on the flow field. The characteristics of moisture ventilation were improved by 20% and 40% in terms of the 1st scale of ventilation efficiency(SVE1) and the 2nd scale of ventilation efficiency (SVE2)respectively, through the modifications of design variables such as the addition of inlets, outlets and partition. A significant improvement in the characteristic ventilation time and the moisture exhaust efficiency was also made by these modifications. |