Title |
Performance and Flow Characteristics of Axial Fan |
Keywords |
Axial fan ; 축류팬 ; Performance evaluation ; 성능평가 ; PIV ; 영상유속측정기 ; Bellmouth ; 벨마우스 |
Abstract |
Comprehensive work is done for flows by an axial fan by experimental research. The present model fan is used for air handling device for out-door unit of an air conditioner in home appliance. PIV(Particle Image Velocimetry) system and wind tunnel are adopted for measurements of flows and performance evaluation, respectively. Major experimental conditions are the installation depth of a fan into a bellmouth of it. Optimal position of a fan in an inlet guide tube is observed by examination of fan-performance and flows in both upstream and downstream of the fan. Consequently, in the case of the fan inserted in half depth into the inlet tube, the efficiency of fan shows its maximum value and flow patterns is also streamlined. |