Title Analysis of Woven Wire Wick Structure for a Miniature Heat Pipe
Authors 이진성 ; 김철주
Page pp.18-24
ISSN 12296422
Keywords Woven wire wick ; 편조 윅 ; Effective thermal conductivity ; 유효열전도도 ; Mean porosity ; 평균 다공도 ; Wire helix angle ; 소선 나선각
Abstract Woven wire wick is very effective structure because of its easiness to insert inside of pipe for a miniature heat pipe. The present study was conducted to investigate the effect of the effective flow passage with respect to wire helix angle. Also effective thermal conductivity were examined by defining mean porosity considering effective liquid flow passages. Effective heat transfer area is varied with respect to wire helix angle, and in the range of =60∼65 , heat transfer area is decreased about 15∼20%. Permeability of woven wire wick shows similar value of 200 mesh screen wick. And comparison of experimental results on effective thermal conductivity shows a fairly good agreement with the analytical results.