Title |
Experimental Study on the Performance Improvement of Aluminum Grooved Heat Pipe due to increased number of Grooves |
Authors |
홍진관 ; 최상곤 ; 김대성 ; 정원복 ; 변윤식 ; 양권옥 |
Keywords |
Heat pipe ; 히트파이프 ; Axial groove ; 축방향 그루브 ; Tilt angle ; 경사각 ; Filling ratio ; 충전율 ; Thermal resistance ; 열저항 ; Performance test ; 성능시험 |
Abstract |
Aluminum/Freon22 grooved heat pipes which have 26 axial grooves in a cross-section were manufactured and tested. The performance test was conducted by varying filling ratio and tilt angle. Operation limit, thermal resistance, overall heat transfer coefficient were investigated. The experimental result was compared with previous study which conducted in the case of a heat pipe with combined wick. The experimental result shows that thermal resistance of this heat pipe is twice smaller than that of the heat pipe with combined wick and operation limit is increased about 75%, comparing with that of heat pipe with combined wick. |