ACI Committee 318, 2014, Building Code Requirements for Structural Concrete and Commentary (ACI 318M-14), armington Hills, Michigan, USA: American Concrete Institute (ACI), pp. 519Google Search
2 
ACI Committee 374, 2005, Acceptance Criteria for Moment Frames Based on Structural Testing and Commentary (ACI 374.1-05), Farmington Hills, Michigan, USA: American Concrete Institute (ACI), pp. 9Google Search
3 
Choi C. S., Kim S. H., Choi Y. C., Choi H. K., 2013, Analytical Study on Hybrid Precast Concrete Beam-Column Connections, Journal of the Korea Concrete Institute, Vol. 25, No. 6, pp. 631-639DOI
4 
Choi S. H., Hwang J. H., Heo I., Kim K. S., Woo W. T., 2018, Flexural Response of Negative Moment Region of Hybrid Prestressed Precast Concrete (HPPC) System, Journal of Architectural Institute of Korea, Vol. 34, No. 10, pp. 3-10Google Search
5 
El-Sheikh M. T., Sause R., Pessiki S., Lu L. W., 1999, Seismic Behavior and Design of Unbonded Post-Tensioned Precast Concrete Frames, PCI Journal, Vol. 44, No. 3, pp. 54-71Google Search
6 
Hwang J H., Choi S H., Kim J H., Kim K S., Woo W T., 2018, Reversed Cyclic Behavior of Post-Tensioned Precast Concrete Beam-Column Connections with Unbonded Tendons, Journal of the Korea Concrete Institute, Vol. 30, No. 6, pp. 657-664Google Search
7 
Hwang J H., Choi S H., Lee D H., Kim K S., Woo W T., 2017, Reversed Cyclic Loading Test of Post-Tensioned Precast Concrete Beam-Column Connections with 2,400 MPa Prestressing Strands., Journal of the Architectural Institute of Korea Structure & Construction, Vol. 33, No. 12, pp. 45-52Google Search
8 
IBC, 2000, International Building Code (IBC 2000), Final Draft, July 1998, Falls Church. Va. USA; International Code Council (ICC)Google Search
9 
KCI, 2012, Concrete Design Code and Commentary, Seoul, Korea; Korea Concrete Institute (KCI). (In Korean)Google Search
10 
Lee D. J., Lee J. D., Oh T. S., Kang T. H. K., 2014, Seismic Experiment of Precast Concrete Exterior Beam-Column Joint Using Bolt Type Connection and Prestressing MEthod, Journal of the Korea Concrete Institute, Vol. 26, No. 2, pp. 125-133DOI
11 
Nakano K., Tanabe K., Matsuzaki Y., Wada A., Sakata H., Kuboyama H,, 2004, Experimental Study on Mechanical Behavior of Damage Controlled Precast-Prestressed Concrete Structure with P/C MILD-PRESS-JOINT, Proceedings of the 13th WCEE, Paper No, 2778Google Search
12 
Priestley M. N., Tao J. R., 1993, Seismic Response of Precast Prestressed Concrete Frames with Partially Debonded Tendons, PCI Journal, Vol. 38, No. 1, pp. 58-69Google Search
13 
Sakata H., Kuboyama H., Sugiyama T., Ikezawa M., Wada A., Matuzaki Y, Machida S, Nakano K, 2005, Experimental Study on Beam-Column Joint of Damage Controlled Precast-Prestressed Concrete Frame with P/C MILD-PRESS-JOINT, Journal of Structural and Construction Engineering, Vol. 588, pp. 141-147Google Search
14 
Wada A., Sakata H., Nakano K., Matsuzaki Y., Tanabe K., Machida S., 2006, Study on Damage Controlled Precast-Prestressed Concrete Structure with P/C MILD-PRESS-JOINT-Part 1: Overview of P/C Mild-Press-Joint Building Construction and its Practical Applications, In Proceedings of the 2nd FIB Congress, Vol. 400Google Search