Mobile QR Code QR CODE
Export citation EndNote

References

1 
ANSYS, Inc , 2019, ANSYS Mechanical APDL Element Reference, Canonsburg, PA; ANSYS, Inc.Google Search
2 
Cho S. G., Kim D., Chaudhary S., 2011, A Simplified Model for Nonlinear Seismic Response Analysis of Equipment Cabinets in Nuclear Power Plants, Nuclear Engineering and Design, Vol. 241, No. 8, pp. 2750-2757DOI
3 
Choi I. K., Choun Y. S., Ahn S. M., Seo J. M., 2008, Probabilistic Seismic Risk Analysis of CANDU Containment Structure for Near-Fault Earthquakes, Nuclear Engineering and Design, Vol. 238, No. 6, pp. 1382-1391DOI
4 
CSI , 2013, SAP2000, C. S. I., Computers and Structures Inc (CSI). Berkeley, CA, USA.Google Search
5 
De Grandis S., Domaneschi M., Perotti F., 2009, A Numerical Procedure for Computing the Fragility of NPP Components under Random Seismic Excitation, Nuclear Engineering and Design, Vol. 239, No. 11, pp. 2491-2499DOI
6 
Huang X., Kwon O. S., Bentz E., Tcherner J., 2018, Method for Evaluation of Concrete Containment Structure Subjected to Earthquake Excitation and Internal Pressure Increase, Earthquake Engineering & Structural Dynamics, Vol. 47, No. 6, pp. 1544-1565DOI
7 
Hur J., Althoff E., Sezen H., Denning R., Aldemir T., 2017, Seismic Assessment and Performance of Nonstructural Components Affected by Structural Modeling, Nuclear Engineering and Technology, Vol. 49, No. 2, pp. 387-394DOI
8 
Lu Y., Panagiotou M., 2014, Three-Dimensional Cyclic Beam-Truss Model for Nonplanar Reinforced Concrete Walls, Journal of Structural Engineering, Vol. 140, No. 3, pp. 04013071DOI
9 
Mazzoni S., McKenna F., Scott M. H., Fenves G. L., 2006, OpenSees Command Language Manual, Pacific Earthquake Engineering Research (PEER) Center, Vol. centerURL
10 
Miao Z. W., Lu X. Z., Jiang J. J., Ye L. P., 2006, Nonlinear FE Model for RC Shear Walls Based on Multi-Layer Shell Element and Microplane Constitutive Model, Computational Methods in Engineering and Science, pp. 21-23URL
11 
Nakamura N., Akita S., Suzuki T., Koba M., Nakamura S., Nakano T., 2010, Study of Ultimate Seismic Response and Fragility Evaluation of Nuclear Power Building Using Nonlinear Three-Dimensional Finite Element Model, Nuclear Engineering and Design, Vol. 240, No. 1, pp. 166-180DOI
12 
Nguyen D. D., Thusa B., Han T. S., Lee T. H., 2020, Identifying Significant Earthquake Intensity Measures for Evaluating Seismic Damage and Fragility of Nuclear Power Plant Structures, Nuclear Engineering and Technology, Vol. 52, No. 1, pp. 192-205DOI
13 
Nguyen D. D., Thusa B., Park H., Azad M. S., Lee T. H., 2021, Efficiency of Various Structural Modeling Schemes on Evaluating Seismic Performance and Fragility of APR 1400 Containment Building, Nuclear Engineering and Technology, Vol. 53, No. 8, pp. 2696-2707DOI
14 
NRC , 2014, US Nuclear Regulatory Commission 1.60: Design Response Spectra for Seismic Design of Nuclear Power Plants, Regulatory Guide 1.60, Revision 2, Rockville, Maryland, USA.Google Search
15 
Pandey M. D., 1997, Reliability-Based Assessment of the Integrity of Bonded Prestressed Concrete Containment Structures, Nuclear Engineering and Design, Vol. 176, No. 3, pp. 247-260DOI
16 
PEER Center., 2020, PEER Ground Motion Database, Pacific Earthquake Engineering Research Center, University of California, Berkeley, CA, USA. http://ngawest2.berkeley.edu.URL
17 
SeismoSoft , 2017, SeismoSignal - A Computer Program for Signal Processing of Strong-Motion Data, available from http://www.seismosoft.comURL
18 
Yang K. Y., Song J. K., Kim J. S., 2019, Evaluation of Embedment Effect in Soil-Structure Interaction Analysis considering Dynamic Characteristics of Nuclear Power Plant Structure and Soil, Journal of the Korea Concrete Institute, Vol. 31, No. 5, pp. 437-447Google Search